TY - JOUR
T1 - Volumetric hand-held optoacoustic angiography as a tool for real-time screening of dense breast
AU - Deán-Ben, X.L.
AU - Fehm, T.F.
AU - Gostic, M.
AU - Razansky, D.
N1 - D.R. acknowledges support from the European Union under grant agreement ERC-2010-StG-260991.
PY - 2015
Y1 - 2015
N2 - Existing mammographic screening solutions are generally associated with several major drawbacks, such as exposure to ionizing radiation or insufficient sensitivity in younger populations with radiographically-dense breast. Even when combined with ultrasound or magnetic resonance imaging, X-Ray mammography may still attain unspecific or false positive results. Thus, development of new breast imaging tools represents a timely medical challenge. We report on a new approach to high-resolution functional and anatomical breast angiography using volumetric hand-held optoacoustic tomography, which employs light intensities safe for human use. Experiments in young healthy volunteers with fibroglandular-dominated dense breasts revealed the feasibility of rendering three-dimensional images representing vascular anatomy and functional blood oxygenation parameters at video rate. Sufficient contrast was achieved at depths beyond 2 cm within dense breasts without compromising the real-time imaging performance. The suggested solution may thus find applicability as a standalone or supplemental screening tool for early detection and follow-up of carcinomas in radiographically-dense breasts. Volumetric handheld optoacoustic tomography scanner uses safe pulses of near-infrared light to render three-dimensional images of deep vascular anatomy, blood oxygenation and breast parenchyma at video rate.
AB - Existing mammographic screening solutions are generally associated with several major drawbacks, such as exposure to ionizing radiation or insufficient sensitivity in younger populations with radiographically-dense breast. Even when combined with ultrasound or magnetic resonance imaging, X-Ray mammography may still attain unspecific or false positive results. Thus, development of new breast imaging tools represents a timely medical challenge. We report on a new approach to high-resolution functional and anatomical breast angiography using volumetric hand-held optoacoustic tomography, which employs light intensities safe for human use. Experiments in young healthy volunteers with fibroglandular-dominated dense breasts revealed the feasibility of rendering three-dimensional images representing vascular anatomy and functional blood oxygenation parameters at video rate. Sufficient contrast was achieved at depths beyond 2 cm within dense breasts without compromising the real-time imaging performance. The suggested solution may thus find applicability as a standalone or supplemental screening tool for early detection and follow-up of carcinomas in radiographically-dense breasts. Volumetric handheld optoacoustic tomography scanner uses safe pulses of near-infrared light to render three-dimensional images of deep vascular anatomy, blood oxygenation and breast parenchyma at video rate.
KW - Photoacoustic imaging
KW - Optoacoustic tomography
KW - Hand-held scanner
KW - Breast screening
KW - Clinical translation
UR - http://onlinelibrary.wiley.com/doi/10.1002/jbio.201500008/suppinfo
U2 - 10.1002/jbio.201500008
DO - 10.1002/jbio.201500008
M3 - Article
SN - 1864-063X
JO - Journal of Biophotonics
JF - Journal of Biophotonics
ER -