T1 - Systematic review of the agreement of tonometers with Goldmann applanation tonometry
AU - Cook, J. A.
AU - Botello, A. P.
AU - Elders, A.
AU - Ali, A. Fathi
AU - Azuara-Blanco, A.
AU - Fraser, C.
AU - McCormack, K.
AU - Burr, Jennifer Margaret
AU - Group(), Surveillance of Ocular Hypertension Study
N1 - This review was part of the Surveillance for Ocular Hypertension study funded by the UK National Institute for Health Research Health Technology Assessment Programme (Project No. 07/46/02).
PY - 2012/8
Y1 - 2012/8
N2 - OBJECTIVE: To assess the agreement of tonometers available for clinical practice with the Goldmann applanation tonometer (GAT), the most commonly accepted reference device. DESIGN: A systematic review and meta-analysis of directly comparative studies assessing the agreement of 1 or more tonometers with the reference tonometer (GAT). PARTICIPANTS: A total of 11 582 participants (15 525 eyes) were included. METHODS: Summary 95% limits of agreement (LoA) were produced for each comparison. MAIN OUTCOME MEASURES: Agreement, recordability, and reliability. RESULTS: A total of 102 studies, including 130 paired comparisons, were included, representing 8 tonometers: dynamic contour tonometer, noncontact tonometer (NCT), ocular response analyzer, Ocuton S, handheld applanation tonometer (HAT), rebound tonometer, transpalpebral tonometer, and Tono-Pen. The agreement (95% limits) seemed to vary across tonometers: 0.2 mmHg (-3.8 to 4.3 mmHg) for the NCT to 2.7 mmHg (-4.1 to 9.6 mmHg) for the Ocuton S. The estimated proportion within 2 mmHg of the GAT ranged from 33% (Ocuton S) to 66% and 59% (NCT and HAT, respectively). Substantial inter- and intraobserver variability were observed for all tonometers. CONCLUSIONS: The NCT and HAT seem to achieve a measurement closest to the GAT. However, there was substantial variability in measurements both within and between studies. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
AB - OBJECTIVE: To assess the agreement of tonometers available for clinical practice with the Goldmann applanation tonometer (GAT), the most commonly accepted reference device. DESIGN: A systematic review and meta-analysis of directly comparative studies assessing the agreement of 1 or more tonometers with the reference tonometer (GAT). PARTICIPANTS: A total of 11 582 participants (15 525 eyes) were included. METHODS: Summary 95% limits of agreement (LoA) were produced for each comparison. MAIN OUTCOME MEASURES: Agreement, recordability, and reliability. RESULTS: A total of 102 studies, including 130 paired comparisons, were included, representing 8 tonometers: dynamic contour tonometer, noncontact tonometer (NCT), ocular response analyzer, Ocuton S, handheld applanation tonometer (HAT), rebound tonometer, transpalpebral tonometer, and Tono-Pen. The agreement (95% limits) seemed to vary across tonometers: 0.2 mmHg (-3.8 to 4.3 mmHg) for the NCT to 2.7 mmHg (-4.1 to 9.6 mmHg) for the Ocuton S. The estimated proportion within 2 mmHg of the GAT ranged from 33% (Ocuton S) to 66% and 59% (NCT and HAT, respectively). Substantial inter- and intraobserver variability were observed for all tonometers. CONCLUSIONS: The NCT and HAT seem to achieve a measurement closest to the GAT. However, there was substantial variability in measurements both within and between studies. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
U2 - 10.1016/j.ophtha.2012.02.030
DO - 10.1016/j.ophtha.2012.02.030
M3 - Article
SN - 0161-6420
VL - 119
SP - 1552
EP - 1557
JO - Ophthalmology
JF - Ophthalmology
IS - 8
ER -