Abstract
We report both extracavity and intracavity simultaneous second-harmonic generation and compression of pulses at 1.25 mu m from a synchronously pumped RbTiOAsO4-based optical parametric oscillator, using an aperiodically poled crystal of KTiOPO4. The 290-fs input pulses were temporally compressed to 120 fs, with average output powers as great as 120 mW. The experimental results are compared with a numerical model that uses data obtained by characterization of the input pulses by use of the frequency-resolved optical gating technique. (C) 1999 Optical Society of America.
Original language | English |
---|---|
Pages (from-to) | 1071-1073 |
Number of pages | 3 |
Journal | Optics Letters |
Volume | 24 |
Publication status | Published - 1 Aug 1999 |
Keywords
- 2ND-HARMONIC GENERATION