Abstract

We demonstrate application-grade monomode distributed feedback (DFB) laser devices with emission wavelength around 5.2 mu m; suitable for nitric oxide sensing. The devices are based on interband cascade laser material that enables continuous wave operation in the midinfrared spectral region when mounted on a standard thermoelectrically cooled TO-style header. With etched vertical sidewall DFB gratings as wavelength selective elements, signal to noise ratios around 30 dB and typical tuning ranges greater than 12 nm were achieved, making the devices suitable for applications based on tunable laser absorption spectroscopy.

Original languageEnglish
Pages (from-to)480-482
Number of pages3
JournalIEEE Photonics Technology Letters
Volume26
Issue number5
Early online date2 Jan 2014
DOIs
Publication statusPublished - 1 Mar 2014

Keywords

  • Distributed feedback (DFB) laser
  • interband cascade laser (ICL)
  • midinfrared
  • nitric oxide (NO) sensing
  • semiconductor laser
  • tunable laser absorption spectroscopy (TLAS)
  • Room temperature

Fingerprint