TY - JOUR
T1 - High performance direct absorption spectroscopy of pure and binary mixture hydrocarbon gases in the 6 - 11 μm range
AU - Heinrich, Robert
AU - Popescu, Alexandru
AU - Hangauer, Andreas
AU - Strzoda, Rainer
AU - Höfling, Sven
N1 - The project has received funding from the European Unions Horizon 2020 research and innovation program under grant agreement No 636930.
PY - 2017/8
Y1 - 2017/8
N2 - The availability of accurate and fast hydrocarbon analyzers, capable of real-time operation while enabling feedback-loops, would lead to a paradigm change in the petro-chemical industry. Primarily gas chromatographs measure the composition of hydrocarbon process streams. Due to sophisticated gas sampling, these analyzers are limited in response time. As hydrocarbons absorb in the mid-infrared spectral range, the employment of fast spectroscopic systems is highly attractive due to significantly reduced maintenance costs and the capability to setup real-time process control. New developments in mid-infrared laser systems pave the way for the development of high-performance analyzers provided that accurate spectral models are available for multi-species detection. In order to overcome current deficiencies in the availability of spectroscopic data, we developed a laser-based setup covering the 6–11 μm wavelength range. The presented system is designated as laboratory reference system. Its spectral accuracy is at least 6.6×10−3 cm−1 with a precision of 3×10−3 cm−1. With a “per point” minimum detectable absorption of 1.3×10−3 cm−1 Hz−1/2 it allows us to perform systematic measurements of hydrocarbon spectra of the first 7 alkanes under conditions which are not tabulated in spectroscopic database. We exemplify the system performance with measured direct absorption spectra of methane, propane, iso-butane, and a mixture of methane and propane.
AB - The availability of accurate and fast hydrocarbon analyzers, capable of real-time operation while enabling feedback-loops, would lead to a paradigm change in the petro-chemical industry. Primarily gas chromatographs measure the composition of hydrocarbon process streams. Due to sophisticated gas sampling, these analyzers are limited in response time. As hydrocarbons absorb in the mid-infrared spectral range, the employment of fast spectroscopic systems is highly attractive due to significantly reduced maintenance costs and the capability to setup real-time process control. New developments in mid-infrared laser systems pave the way for the development of high-performance analyzers provided that accurate spectral models are available for multi-species detection. In order to overcome current deficiencies in the availability of spectroscopic data, we developed a laser-based setup covering the 6–11 μm wavelength range. The presented system is designated as laboratory reference system. Its spectral accuracy is at least 6.6×10−3 cm−1 with a precision of 3×10−3 cm−1. With a “per point” minimum detectable absorption of 1.3×10−3 cm−1 Hz−1/2 it allows us to perform systematic measurements of hydrocarbon spectra of the first 7 alkanes under conditions which are not tabulated in spectroscopic database. We exemplify the system performance with measured direct absorption spectra of methane, propane, iso-butane, and a mixture of methane and propane.
U2 - 10.1007/s00340-017-6796-6
DO - 10.1007/s00340-017-6796-6
M3 - Article
SN - 0946-2171
VL - 123
JO - Applied Physics B: Lasers and Optics
JF - Applied Physics B: Lasers and Optics
M1 - 223
ER -