Abstract
A new electrochemical cell for CO2 sensing has been set up using garnet-like solid electrolyte Li6BaLa2Ta 2O12 and Li0.36WO3 as a reference electrode. The electromotive force (EMF) of the cell, the reproducibility and the long-term stability of the sensor signals have been examined at temperature between 300 and 500 °C. The EMF was found to be dependent on the partial pressure of CO2 (pCO2) and could be expressed by the Nernst equation. The sensitivity of the sensors was 73 mV/decade and 75 mV/decade at 450 and 500 °C, respectively. It was also seen that the sensor showed fast response for CO2 and the sensor signals was found to be highly reproducible and stable for several days.
Original language | English |
---|---|
Pages (from-to) | 284-289 |
Number of pages | 6 |
Journal | Sensors and Actuators, B: Chemical |
Volume | 176 |
DOIs | |
Publication status | Published - 2013 |
Keywords
- Garnet-like
- Gas sensor