A marking of the cricothyroid membrane with extended neck returns to correct position after neck manipulation and repositioning

James Bowness, Wendy H Teoh, Michael Seltz Kristensen, Andrew Dalton, Alexander Le Saint-Grant, Alasdair Taylor, Simon Crawley, Fraser Chisholm, Ourania Varsou, Barry McGuire

Research output: Contribution to journalArticlepeer-review

Abstract

Background

Emergency front of neck airway access by anaesthetists carries a high failure rate and it is recommended to identify the cricothyroid membrane before induction of anaesthesia in patients with a predicted difficult airway. We have investigated whether a marking of the cricothyroid membrane done in the extended neck position remains correct after the patient’s neck has been manipulated and subsequently repositioned

Methods

The subject was first placed in the extended head and neck position and had the cricothyroid membrane identified and marked with three methods, palpation, ‘laryngeal handshake’ and ultrasonography and the distance from the suprasternal notch to the cricothyroid membrane was measured.

The subject then moved off the table and sat on a chair and subsequently returned to the extended neck position and examinations were repeated.

Results

Skin markings of all 11 subjects lay within the boundaries of the cricothyroid membrane when the subject was repositioned back to the extended neck position and the median difference between the two measurements of the distance from the suprasternal notch was 0 mm (range 0‐2 mm).

Conclusion

The cricothyroid membrane can be identified and marked with the subject in the extended neck position.

Then the patient’s position can be changed as needed, for example to the ‘sniffing’ neck position for conventional intubation. If a front of neck airway access is required during subsequent airway management, the patient can be returned expediently to the extended‐neck position, and the marking of the centre of the membrane will still be in the correct place.

Original languageEnglish
Pages (from-to)1422-1425
Number of pages4
JournalActa Anaesthesiologica Scandinavica
Volume64
Issue number10
Early online date10 Aug 2020
DOIs
Publication statusPublished - Nov 2020

Keywords

  • Cricoid Cartilage
  • Humans
  • Intubation, Intratracheal
  • Neck/diagnostic imaging
  • Palpation
  • Thyroid Cartilage/diagnostic imaging
  • Ultrasonography

Fingerprint

Dive into the research topics of 'A marking of the cricothyroid membrane with extended neck returns to correct position after neck manipulation and repositioning'. Together they form a unique fingerprint.

Cite this