Description
The High Performance Liquid Chromatography (HPLC) data have been acquired using either a Shimadzu HPLC consisting of a DGU-20A5 degassing unit, LC-20AT liquid chromatography pump, SIL-20AHT autosampler, CMB-20A communications bus module, SPD-M20A diode array detector and a CTO-20A column oven; or a Shimadzu HPLC consisting of a DGU-20A5R degassing unit, LC-20AD liquid chromatography pump, SIL-20AHT autosampler, SPD-20A UV/Vis detector and a CTO-20A column oven. Separation was achieved using DAICEL CHIRALPAK AD H, AS-H and IB and CHIRALCEL OD-H columns using the method stated. The raw data files are in .lcd format; the proprietary software which would allow for visualisation of the data and their analysis is Lab Solutions (LabSolutions CS : SHIMADZU (Shimadzu Corporation)). The processed data are in .pdf format, and can be opened using any pdf viewing application, including but not limited to Adobe Acrobat Reader (link) and Google Chrome.
The Infrared Radiation (IR) data were acquired using a Shimadzu IRAffinity-1 Fourier transform IR spectrophotometer fitted with a Specac Quest ATR accessory (diamond puck). The raw data files are in .smf format; the proprietary software which would allow for visualisation of the data and their analysis is IRSolution (IRsolution Optional software : Shimadzu (United Kingdom)). The processed data are in .pdf format, and can be opened using any pdf viewing application, including but not limited to Adobe Acrobat Reader (link) and Google Chrome.
High resolution mass spectrometry (HRMS) data were acquired by either electrospray ionisation (ESI), electron impact (EI), atmospheric pressure chemical ionization (APCI) or nanospray ionization (NSI). The data are in .pdf format, and can be opened using xxx, or are in .docx format, and can be opened using any word processor (Notepad, Word etc.).
Nuclear Magnetic Resonance (NMR) spectra were acquired on either a Bruker Avance II 400 (1H 400 MHz; 13C{1H} 101 MHz, 31P{1H} 162 MHz, 19F{1H} 376 MHz) or a Bruker Avance II 500 (1H 500 MHz; 13C{1H} 126 MHz, 31P{1H} 202 MHz, 19F{1H} 471 MHz) spectrometer. The raw data files are in .zip format (containing a number of .fid, .txt, .info, .par, .output and .temp files), and can be opened using any proprietary NMR processing software, including but not limited to NMRium (NMRium - Visualize, analyze and process NMR spectra online), Mestrelab MNOVA (Mnova Software Suite - Mestrelab) and Bruker Topspin (TopSpin | NMR Data Analysis | Bruker). The processed data files are are in .mova format, and can be opened using the following proprietary software (Mestrelab MNOVA (Mnova Software Suite - Mestrelab), Bruker Topspin (TopSpin | NMR Data Analysis | Bruker)).
The Infrared Radiation (IR) data were acquired using a Shimadzu IRAffinity-1 Fourier transform IR spectrophotometer fitted with a Specac Quest ATR accessory (diamond puck). The raw data files are in .smf format; the proprietary software which would allow for visualisation of the data and their analysis is IRSolution (IRsolution Optional software : Shimadzu (United Kingdom)). The processed data are in .pdf format, and can be opened using any pdf viewing application, including but not limited to Adobe Acrobat Reader (link) and Google Chrome.
High resolution mass spectrometry (HRMS) data were acquired by either electrospray ionisation (ESI), electron impact (EI), atmospheric pressure chemical ionization (APCI) or nanospray ionization (NSI). The data are in .pdf format, and can be opened using xxx, or are in .docx format, and can be opened using any word processor (Notepad, Word etc.).
Nuclear Magnetic Resonance (NMR) spectra were acquired on either a Bruker Avance II 400 (1H 400 MHz; 13C{1H} 101 MHz, 31P{1H} 162 MHz, 19F{1H} 376 MHz) or a Bruker Avance II 500 (1H 500 MHz; 13C{1H} 126 MHz, 31P{1H} 202 MHz, 19F{1H} 471 MHz) spectrometer. The raw data files are in .zip format (containing a number of .fid, .txt, .info, .par, .output and .temp files), and can be opened using any proprietary NMR processing software, including but not limited to NMRium (NMRium - Visualize, analyze and process NMR spectra online), Mestrelab MNOVA (Mnova Software Suite - Mestrelab) and Bruker Topspin (TopSpin | NMR Data Analysis | Bruker). The processed data files are are in .mova format, and can be opened using the following proprietary software (Mestrelab MNOVA (Mnova Software Suite - Mestrelab), Bruker Topspin (TopSpin | NMR Data Analysis | Bruker)).
| Date made available | 8 Oct 2025 |
|---|---|
| Publisher | University of St Andrews |
-
Allan Watson Programme Grant: Boron: Beyond the Reagent
Watson, A. (PI), Morris, R. (CoI), Smith, A. (CoI) & Zysman-Colman, E. (CoI)
1/05/23 → 30/04/28
Project: Standard
Research output
- 1 Article
-
From oxygen to tellurium: the impact of the chalcogen on nucleophilicities and basicities of isochalcogenourea catalysts
Stockhammer, L., Kasten, K., Eitzinger, A., Vogl, L. S., Piringer, M., Weinzierl, D., Ofial, A. R., Smith, A. D. & Waser, M., 23 Oct 2025, (E-pub ahead of print) In: Angewandte Chemie International Edition. Early View, 15 p., e202514865.Research output: Contribution to journal › Article › peer-review
Open AccessFile
Datasets
-
CCDC 2452429: Experimental Crystal Structure Determination
Stockhammer, Lotte (Creator), Kasten, Kevin (Creator), Eitzinger, Andreas (Creator), Vogl, Lukas S. (Creator), Piringer, Magdalena (Creator), Weinzierl, David (Creator), Ofial, Armin R. (Creator), Smith, Andrew D. (Creator) & Waser, Mario (Creator), Cambridge Crystallographic Data Centre, 2025
DOI: 10.5517/ccdc.csd.cc2n9ymk
Dataset